Water treatment

Odoo afbeelding en tekstblok

General Introduction

RO equipment generally consist of raw water pre-treatment system, reverse osmosis purification system, super purification,post purification treatment system. Pre-treatment system aim to make the raw water quality meet the input water quality requirement of reverse osmosis membrane and guarantee the steady working of reverse osmosis purification system, which is the most economic and efficient purification way to eliminate 98% of ions, organism and 100% of microorganism (theoretically) in the raw water all at once. The super purification treatment system further eliminate the remain micro-ion and microorganism through multiple integration technology to meet the final water quality requirement in different usage.

Van 250 l/u tot 20.000 l/u

Compleet gebouwd op skid klaar voor inbedrijfname onsite - Siemens PLC sturing en TouchPanel - INOX 316 / 304 - UV lampen - IonPure EDI/CDI www.lenntech.com/products/evoqua-ionpure.htm

Output water conductivity: <1us/com

Level: Compliance with GMP, FDA requirements

Systeem met enkele RO-filter

  1. Voorbehandeling (zandfilter en actieve koolfilter)

  2. RO-filter

  3. UV-licht

Dubbele RO-filter

  1. Zandfilter

  2. Actieve koolfilter

  3. Buffertank

  4. LD pomp

  5. Precisiefilter

  6. Eerste RO

  7. Tweede RO

  8. Buffertank met puur warer

  9. HD pomp

Dubbele RO-filter en EDI

  1. Zandfilter

  2. Actieve koolfilter

  3. Buffertank

  4. HD pomp

  5. Precisiefilter

  6. Eerste RO

  7. Sanitizatietank (met circulatie over UV-lamp)

  8. HD pomp

  9. Precisiefilter

  10. Tweede RO

  11. Sanitizatietank (met circulatie over UV-lamp)

  12. EDI (Ion-Pure)

  13. Sanitizatietank

  14. Afnamepomp

Odoo afbeelding en tekstblok

...